ZW32-12 type outdoor high-voltage vacuum circuit breaker is used in three-phase power system of AC 50Hz, rated voltage 10kV to 12kV, as breaking, making load current. Also, the circuit breaker has the function of overload and short circuit protection, controlling, measuring, remote control and remote monitoring. This circuit breaker is applied in industrial and mining enterprises, power plant and substation for electric equipment's control and protection, and also it can be used on the occasion of frequent operation of rural power grids due to circuit breaker's repeatedly interrupting and fast reclosing ability.
Ambient conditions:
1.Air temperature: Maximum temperature + 40℃, Minimum temperature-40℃;
2.Air relative humidity: Daily average humidity no more than 95%, oMonthly average humidity less than 90%;
3.Altitude above sea level: not exceed 2000m;
4.Wind pressure not more than 700 Pa (equivalent to wind speed 34 m/s);
5.Earthquake:not more than level eight;
6.No fire, explosion, serious, chemical corrosion and violent vibration.
Main technical parameters of ZW32-12 outdoor high voltage vacuum circuit breaker:
No | Item | Unit | Value |
1 | Rated voltage | kV | 12 |
2 | Rated current | A | 200/400/630 |
3 | Rated short current breaking current | kA | 12.5/16/20 |
4 | Power frequency withstand voltage | dry | kV | 42 |
wet | 34 |
5 | Lightning impulse withstand voltage | 75 |
6 | Rated operation sequence |
| O-0.3s-CO-180s-CO |
7 | Breaking operations of rated short-circuit breaking current | times | 30 |
8 | Rated short circuit making current (peak) | kA | 50 |
9 | Rated peak withstand current | kA | 50 |
10 | Rated short circuit withstand current | kA | 20 |
11 | Rated short time duration | s | 4 |
12 | Opening time (tripping) | Max. operation voltage | ms | 15~50 |
Rated operation voltage |
Min. operation voltage | 30~60 |
13 | Closing time | ms | 25~60 |
14 | Total breaking time | ms | ≤100 |
15 | Arcing time | ms | ≤20 |
16 | Mechanical endurance | times | 10000 |
17 | Rated input power of charging motor | W | 40 |
18 | Rated voltage of secondary circuit | V | DC220,110,24 |
19 | Charging time under rated voltage | s | ≤10 |
20 | Overcurrent tripping | Rated current | A | 5 |
Tripping current accuracy | % | ±1 |
ZW32-12 outdoor high voltage vacuum circuit breaker drawing:
![](//img.hisupplier.com/var/userImages/2014-08/04/142002088865.jpg)
Production scenes:
![](//img.hisupplier.com/var/userImages/2014-08/06/152214855896.jpg)
![](//img.hisupplier.com/var/userImages/2014-08/06/152221813562.jpg)
Category: Outdoor Vacuum Circuit Breaker